BAIJIAN - a professional third-party testing and inspection platform that provides related testing and inspection services such as testing 1 food (sac
This standard specifies the method for the determination of benzoic acid, sorbic acid, and saccharin sodium in food. The first method of this standard is applicable to the determination of benzoic acid, sorbic acid, and saccharin sodium in food; The second method is applicable to the determination of benzoic acid and sorbic acid in soy sauce, fruit juice, and jam. The first method is liquid chromatography. The sample is extracted with water. The high fat sample is defatted with n-hexane, and the high protein sample is precipitated with a protein precipitant. The liquid phase chromatography is used for separation, and the UV detector is used for detection. The external standard method is used for quantification. Unless otherwise specified, all reagents and materials used in this method are analytical pure. Water is the first grade water specified in GB/T 6682. 3.1 Reagent 3.1.1 Ammonia (NH, ● H2O). 3.1.2 Potassium ferrocyanide [K, Fe (CN). ● 3H, 0]. 3.1.3 Zinc acetate [Zn (CH, C0O) 2 ● 2H: O]. 3.1.4 Anhydrous ethyl alcohol (CH, CH2OH). 3.1.5 n-hexane (C, H). 3.1.6 Methyl alcohol (CH, OH): Chromatically pure. 3.1.7 Ammonium acetate (CH, COONH,): color harmonic purity. 3.1.8 Formic acid (HCO0H): Chromatically pure. 3.2 Reagent Preparation 3.2.1 Ammonia Water Solution (1+99): Take 1 mL of ammonia water and add it to 99 mL of water, mix well. 3.2.2 Potassium ferrocyanide solution (92 g/L): Weigh 106 g of potassium ferrocyanide, add an appropriate amount of water to dissolve, and bring to a constant volume of 1000 mL. 3.2.3 Zinc acetate solution (183 g/L); Weigh 220 g of zinc acetate and dissolve it in a small amount of water, add 30 mL of glacial acetic acid, and bring it to a constant volume of 1000 ml. 3.2.4 ammonium acetate solution (20 mmol/L) with water. Weigh 1.54 g of ammonium acetate, dissolve it in an appropriate amount of water, bring it to a constant volume of 1000 mI with water, and filter it through a 0.22 μ m aqueous phase microporous filter membrane before use. 3.2.5 Formic acid ammonium acetate solution (2 mmol/L formic acid+20 mmol/L ammonium acetate): Weigh 1.54 g of ammonium acetate and add an appropriate amount of water to dissolve
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms
3. Used as a sales report: issuing legally effective testing reports to make consumers more confident
4. Papers and research: Provide professional personalized testing needs
5. Judicial services: providing scientific, fair, and accurate testing data
6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems
BAIJIAN testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations
3. Mail samples and arrange testing
4. Progress tracking and result feedback
5. Provide reports and after-sales service
6. If urgent or priority processing is required
Our Competitive Edge:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby
3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service
7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc
8. The testing report is authoritative and effective, and is generally used in China
Contact: Mr. Li
Phone: 156-0190-2607
Tel: 400-101-7153
Email: service@Baijiantest.com
Add: No. 700, Yishan Road, Xuhui District, Shangha